{"id":5307,"date":"2023-11-20T15:36:00","date_gmt":"2023-11-20T07:36:00","guid":{"rendered":"https:\/\/www.qhsmt.com\/?p=5307"},"modified":"2023-11-20T08:18:55","modified_gmt":"2023-11-20T00:18:55","slug":"pick-and-place-how-to-interpret-capacitor-markings","status":"publish","type":"post","link":"https:\/\/www.qhsmt.com\/zh\/2023\/11\/20\/pick-and-place-how-to-interpret-capacitor-markings\/","title":{"rendered":"How to Interpret Capacitor Markings"},"content":{"rendered":"

There are many types of capacitor labels compared to resistor labels. It’s difficult to see the markings on small capacitors because of their small body surface area. This article explains how to read the markings on almost all types of modern capacitors manufactured abroad. Your capacitors may be labeled in a different order than the one stated in this article. What’s more, some capacitors lack voltage and tolerance values\u2014you only need a capacitance value to create a low-voltage circuit.Today qihe smt pick and place machine sharing how to Interpret Capacitor Markings<\/p>\n\n\n\n

Understand capacitors and capacitor markings<\/h2>\n\n\n\n
\"Today<\/figure>\n\n\n\n

The function and expression method of capacitor<\/h3>\n\n\n\n

It consists of two metal poles with an insulating medium sandwiched between them. The main characteristic of capacitors is to block DC and AC, so they are often used for interstage coupling, filtering, decoupling, bypassing and signal tuning. The capacitor is represented by “C” plus a number in the circuit, such as C8, which represents the capacitor numbered 8 in the circuit.<\/p>\n\n\n\n

Classification of capacitors<\/h3>\n\n\n\n

Capacitors are divided according to different media: gas dielectric capacitors, liquid dielectric capacitors, inorganic solid dielectric capacitors, organic solid dielectric capacitors and electrolytic capacitors. According to polarity, they are divided into: polarized capacitors and non-polar capacitors. According to the structure, it can be divided into: fixed capacitor, variable capacitor and trimmer capacitor.<\/p>\n\n\n\n

The capacity of the capacitor<\/h3>\n\n\n\n

Capacitance represents the amount of electrical energy that can be stored. The impeding effect of capacitance on AC signals is called capacitive reactance. Capacitive reactance is related to the frequency and capacitance of AC signals. Capacitive reactance XC=1\/2\u03c0f c (f represents the frequency of AC signals and C represents capacitance).<\/p>\n\n\n\n

\"Today<\/figure>\n\n\n\n

The capacity unit and withstand voltage of the capacitor<\/h3>\n\n\n\n

The basic unit of capacitance is F (farad), and other units include: millifarad (mF), microfarad (uF), nanofarad (nF), and picofarad (pF). Since the capacity in unit F is too large, what we see are generally units of \u03bcF, nF, and pF. Conversion relationship: 1F=1000000\u03bcF, 1\u03bcF=1000nF=1000000pF.<\/p>\n\n\n\n

Each capacitor has its withstand voltage value, represented by V. Generally, the nominal withstand voltage values of electrodeless capacitors are relatively high: 63V, 100V, 160V, 250V, 400V, 600V, 1000V, etc. The withstand voltage of polarized capacitors is relatively low. Generally, the nominal withstand voltage values are: 4V, 6.3V, 10V, 16V, 25V, 35V, 50V, 63V, 80V, 100V, 220V, 400V, etc.<\/p>\n\n\n\n

Capacitor labeling method and capacity error<\/h3>\n\n\n\n

The labeling methods of capacitors are divided into: direct marking method, color marking method and numerical marking method. For capacitors with relatively large volumes, the direct scaling method is often used. If it is 0.005, it means 0.005uF=5nF. If it is 5n, it means 5nF.<\/p>\n\n\n\n

Number scale method: Generally, three digits are used to indicate the capacity, the first two digits represent significant digits, and the third digit is the power of 10. For example: 102 means 10x10x10 PF=1000PF, 203 means 20x10x10x10 PF.<\/p>\n\n\n\n

Color marking method uses different colors to represent different numbers along the direction of the capacitor lead. The first and second rings represent the capacitance, and the third color represents the number of zeros after the significant digit (unit is pF). The numerical values represented by the colors are: black=0, brown=1, red=2, orange=3, yellow=4, green=5, blue=6, purple=7, gray=8, white=9.<\/p>\n\n\n\n

The capacitance error is represented by the symbols F, G, J, K, L, and M. The allowable errors are respectively \u00b11%, \u00b12%, \u00b15%, \u00b110%, \u00b115%, and \u00b120%.<\/p>\n\n\n\n

\"Today<\/figure>\n\n\n\n

Distinguish and measure the positive and negative poles of capacitance.<\/h3>\n\n\n\n

The black block with the mark on the capacitor is the negative terminal. There are two semicircles on the PCB at the position of the capacitor. The colored semicircle corresponds to the negative electrode. The length of the pins is also used to distinguish the positive and negative poles. Long pins are positive and short pins are negative.<\/p>\n\n\n\n

When we don’t know the positive and negative poles of the capacitor, we can use a multimeter to measure it. The medium between the two poles of the capacitor is not an absolute insulator, and its resistance is not infinite, but a limited value, generally above 1000 megohms. The resistance between the two poles of the capacitor is called insulation resistance or leakage resistance.<\/p>\n\n\n\n

Only when the positive terminal of the electrolytic capacitor is connected to the positive power supply (black test lead during electrical blocking) and the negative terminal is connected to the negative power supply (red test lead during electrical blocking), the leakage current of the electrolytic capacitor is small (the leakage resistance is large). On the contrary, the leakage current of the electrolytic capacitor increases (the leakage resistance decreases). In this way, we first assume that a certain pole is the “+” pole, and the multimeter selects the R100 or R<\/em>1K block.<\/p>\n\n\n\n

Then the assumed “+” pole is connected to the black test lead of the multimeter, and the other electrode is connected to the red test lead of the multimeter. Note down the scale at which the needle stops (the resistance value is higher if the needle is to the left). For a digital multimeter, the reading can be read directly. Then discharge the capacitor (touch the two leads), then reverse the two test leads and re-measure. In the two measurements, the time the needle last rested on the left (or had a large resistance), the black test lead was connected to the positive electrode of the electrolytic capacitor.<\/p>\n\n\n\n

Some experiences and four misunderstandings about the use of capacitors<\/h3>\n\n\n\n

Some experience: When the polarity of the line cannot be determined in the circuit, it is recommended to use non-polar electrolytic capacitors. The ripple current through the electrolytic capacitor cannot exceed its allowable range. If the specified value is exceeded, capacitors that can withstand large ripple currents need to be selected. The operating voltage of the capacitor cannot exceed its rated voltage. When soldering capacitors, the soldering iron should keep a certain distance from the plastic shell of the capacitor to prevent the plastic sleeve from rupturing due to overheating. And the welding time should not exceed 10 seconds, and the welding temperature should not exceed 260 degrees Celsius.<\/p>\n\n\n\n

Resistance<\/h2>\n\n\n\n
    \n
  1. Parameter identification: The unit of resistance is ohm (\u03a9), and the unit of magnification is: kiloohm (K\u03a9), megaohm (M\u03a9), etc. The conversion method is: 1 megaohm = 1,000 kiloohms = 1,000,000 ohms.
    \u200b<\/li>\n<\/ol>\n\n\n\n

    There are three methods for labeling parameters of resistors, namely direct marking method, color marking method and numerical marking method.<\/p>\n\n\n\n

    a. The numerical standard method is mainly used for small-volume circuits such as patches. For example: 472 means 47\u00d7100\u03a9 (i.e. 4.7K); 104 means 100K.<\/p>\n\n\n\n

    b. The color ring marking method is the most commonly used. Common ones are four-color ring resistors and five-color ring resistors (precision resistors). The last digit represents the allowable deviation, the second to last digit represents the magnification, and the first 2 or 3 digits are significant figures.<\/p>\n\n\n\n

    The meaning of the color circle of the resistor is as shown in the following table:<\/h3>\n\n\n\n

    Color silver gold black brown red orange yellow green blue purple gray white
    Valid figures 0 1 2 3 4 5 6 7 8 9
    Ratio 10^ -2 10^ -1 10^0 10^1 10^2 10^3 10^4 10^5 10^6 10^7 10^8 10^9
    Allowable deviation \u00b110% \u00b15% \u00b11% \u00b12% \u00b10.5% \u00b10.2% \u00b10.1%<\/p>\n\n\n\u9605\u8bfb\u66f4\u591a\uff1aHow to Interpret Capacitor Markings<\/span><\/a>\n\n\n